Pinpoint Test C: Touch Screen Calibration
WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
TEST CONDITIONS
DETAILS/RESULTS/ACTIONS
- C1: TOUCH SCREEN CALIBRATION
- Operate the Valet soft key continuously until the engineering mode screen is displayed (approximately 20 seconds)
- Scroll down and select Touch Calibration
- Select OK
- Tap the touch screen to proceed
- Using a suitable stylus, tap the touch screen at the points indicated until a pass/fail result is displayed
Was the touch screen calibration successful?
- Yes : Calibration complete
- No : Calibration failed. GO to C1.