LEMON Manuals: Even more car manuals for everyone
Home >> Jaguar >> 2022 >> F-Pace R-Dynamic S >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (Battery, Mounting And Cables - Vehicles With: Non-Electric Vehicles -- F-Pace/X761) >> Battery, Mounting And Cables - Vehicles With: Non-Electric Vehicles >> Diagnosis And Testing >> Flat Battery Diagnostics (G2474977) >> Diagnostics And Repair Actions If A Flat Battery Is Suspected >> Pinpoint Test A: Battery Health Checks

Pinpoint Test A: Battery Health Checks

WARNING: This page is about a different variant/trim than selected.
  1. A1: RECORD BATTERY VOLTAGE AND ATTEMPT ENGINE START 
    1. If the vehicle has been recovered to the retailer, then, using a Digital Multi Meter (DMM), record the battery open circuit voltage and make a note of the voltage
    2. Attempt to start the engine

      Does the engine start unaided?

      Yes:  GO to PINPOINT TEST B .

      No:  Complete the RECOVERY CHARGING process using a manufacturer approved battery charger. If either a Midtronics GRX-3080 or GR8-1180 Diagnostic Battery Charger is available, then follow the Recovery Charging procedures as described elsewhere in this article REFER to: BATTERY, MOUNTING AND CABLES - VEHICLES WITH: NON-ELECTRIC VEHICLES .

      FLAT BATTERY DIAGNOSTICS (G2474977) 

      FLAT BATTERY DIAGNOSTICS (G2474977) 

      If no suitable tools (ie: with access to Recovery Charging procedures) are available, then charge the battery for 1 hour. When charging/recovery charging has been completed, then GO to  A2.

  2. A2: BATTERY TESTING 
    1. To confirm the state of battery health, refer to the appropriate Midtronics Battery Diagnostics/Battery Charger procedures and follow the on-screen instructions REFER to: BATTERY, MOUNTING AND CABLES - VEHICLES WITH: NON-ELECTRIC VEHICLES 

      FLAT BATTERY DIAGNOSTICS (G2474977) 

      FLAT BATTERY DIAGNOSTICS (G2474977) 

      FLAT BATTERY DIAGNOSTICS (G2474977) 

      After completion of the battery testing procedures as above, do the results indicate "Good Battery"?

      Yes:  GO to PINPOINT TEST B .

      No:  If using the Midtronics EXP-1080 JLR Hand-Held Battery Diagnostic Equipment, the process flow may result in a "REPLACE BATTERY" decision. In this case, with reference to the appropriate Service information, replace the battery taking care to complete the battery replacement process in order to appropriately clear/reset the BMS  , then GO to PINPOINT TEST B .