LEMON Manuals: Even more car manuals for everyone
Home >> Jaguar >> 2022 >> F-Pace Base >> Repair and Diagnosis >> Engine Mechanical >> Mechanical >> Engine - INGENIUM I4 2.0L Petrol/INGENIUM I4 2.0L Petrol PHEV -- F-Pace/X761 (Specifications - Removal & Installation) >> Engine - INGENIUM I4 2.0L Petrol/INGENIUM I4 2.0L Petrol - PHEV (G2412673) >> Removal And Installation >> Continuous Variable Valve Lift Oil Temperature Sensor (G2148902) >> Installation

Continuous Variable Valve Lift Oil Temperature Sensor (G2148902): Installation

  1. CAUTION:
    • Do not touch the tip of the Continuous Variable Valve Lift (CVVL) oil temperature sensor.
    • Lubricate the threaded section of the Continuous Variable Valve Lift (CVVL) oil temperature sensor with clean engine oil.
    • Install and tighten the CVVL oil temperature sensor.

      Torque  : 18 Nm 

    • Connect the electrical connector to the CVVL oil temperature sensor.
    • Install the breather pipe.
    • Connect the breather pipe.
  2. Install the engine cover.

    Refer to: ENGINE COVER - INGENIUM I4 2.0L PETROL