Removal And Installation: Removal

WARNING: This page is about a different car, the 2018 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Cooling fans may continue to operate after the engine is turned off. They may also start to operate after the engine is turned off and continue operating for up to 10 minutes.
NOTE:
  • This procedure contains some variation in the illustrations depending on the vehicle specification, but the essential information is always correct.
  • This procedure contains illustrations showing certain components removed to provide extra clarity.
  1. Raise and support the vehicle on a suitable 2 post lift.

    Refer to: Lifting .

  2. Disconnect the startup battery ground cable.

    Refer to: Battery Disconnect and Connect .

  3. Partially drain the cooling system.

    Refer to: Cooling System Partial Draining and Vacuum Filling .

  4. Remove the charge air radiator.

    Refer to: Charge Air Cooler .

  5. G11307362

    Remove the vent hose.

  6. G11307363

    Remove the dirty air duct.

  7. CAUTION: Be prepared to collect escaping coolant.
    G11307364

    Disconnect the coolant hoses.

  8. CAUTION: Be prepared to collect escaping coolant.
    G11307365

    Release the 9 clips.

  9. G11307366

    Release the 7 clips.

  10. NOTE: Do not disassemble further if the component is removed for access only.
    G11307367

    Remove the cooling fan motor and shroud.

  11. G11307368

Remove the water pump.