Home >> Jaguar >> 2020 >> XF Checkered Flag >> Repair and Diagnosis >> External Pages >> Different car >> Section 93 (Engine - INGENIUM I4 2.0L Petrol -- XE (X760)) >> Engine - INGENIUM I4 2.0L Petrol >> Description And Operation >> Description >> Variable Camshaft Timing >> Variable Camshaft Timing Actuator

Variable Camshaft Timing Actuator

WARNING: This page is about a different car, the 2018 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
G11308932
ITEM DESCRIPTION
1 Solenoid coil
2 Solenoid core
3 Variable Camshaft Timing (VCT) solenoid assembly
4 Solenoid pintle pin
5 Center bolt
6 Pressurized engine oil
7 Filter
8 Rotor
9 VCT actuator assembly
10 Spool valve

The VCT actuators are operated by the VCT solenoids that are controlled by the Powertrain Control Module (PCM). The PCM can operate the VCT solenoids to move the pintle pin to a predetermined position to control the flow of pressurized engine oil into the VCT actuators.

When the VCT solenoid operates

The solenoid pintle moves towards the spool valve located in the center bolt and makes contact.

Further movement of the solenoid pintle pin will push the spool valve into a known (controlled) position and oil will pass through channels within the center bolt into the VCT actuator chambers. The pressurized engine oil rotates the internal rotor in the VCT actuator which is secured to the camshafts. This in turn changes the engine timing. The total available camshaft advance adjustment is 70°Crankshaft angle towards advance on the intake camshaft and 50°Crankshaft angle on the exhaust camshaft.

Each camshaft VCT actuator has three hydraulic chambers. Residual camshaft torque is used to ensure the VCT actuator is returned to the base position as quickly as possible. The pressurized engine oil is supplied from the engine variable flow oil pump with integral vacuum pump and must be mapped to deliver a controlled oil pressure to the VCT actuator to ensure VCT performance and response times are maintained.