Description And Operation: Operation: Diagnostics

WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.

The FFBHCM monitors the Fuel Fired Booster Heater (FFBH) system for faults. Any faults detected are stored in a volatile memory in the FFBHCM, which can be interrogated by Jaguar approved diagnostic equipment via the High Speed (HS) Controller Area Network (CAN) comfort systems bus. A maximum of three faults and associated freeze frame data can be stored at any one time. If a further fault is detected, the oldest fault is overwritten by the new fault.

The FFBHCM also incorporates an error lockout mode of operation that inhibits operation to prevent serious faults from causing further damage to the system. In the error lockout mode, the FFBHCM immediately stops the FFBH fuel pump, and stops the combustion air fan and coolant pump after the cool down time. Error lockout occurs for start sequence failures, combustion flameouts, heat exchanger casing overheat and if battery voltage is out of limits.