LEMON Manuals: Even more car manuals for everyone
Home >> Jaguar >> 2020 >> XF Checkered Flag >> Repair and Diagnosis >> External Pages >> Different car >> Section 84 (Parking Aid -- XE (X760)) >> Parking Aid >> Description And Operation >> Proximity Camera System - Operation >> System Calibration

System Calibration

WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.

This level of accuracy must be maintained after any service procedures are performed on the vehicle that affects the proximity camera system. Should the control module or any one of the cameras require replacement, static re-calibration must be carried out using the approved Jaguar diagnostic equipment.

Camera replacement is detected by the CCM, through the recognition of a new serial number during the 'camera count' procedure that takes place during the 'ignition on' phase via the Local Interconnect Network (LIN) bus.

If a new camera is installed calibration must be performed using the diagnostic equipment and the vehicle's Touch Screen (TS). During the calibration procedure, setup software in the control module overlays fine colored lines on the TS highlighting reference points on the bodywork. For example, the mirror camera image must capture the side repeater indicator, the shut-line of the doors and the lower sill trim.

Direction arrows are pressed to shift the image in the desired direction to meet the reference points viewed on the TS.

Adjustments include:

When the reference points correspond exactly, the setting is saved and the calibration procedure is complete for that camera.

If body repairs are performed that affect the camera system, a calibration procedure must be executed after the repairs are completed.