LEMON Manuals: Even more car manuals for everyone
Home >> Jaguar >> 2020 >> XF Checkered Flag >> Repair and Diagnosis >> External Pages >> Different car >> Section 82 (Climate Control System - General Information -- XE (X760)) >> Climate Control System - General Information >> Fluorescent Dye Leak Detection >> General Procedures

General Procedures

WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
  1. Check for leaks using ultraviolet (UV) lamp.
    WARNING: Eye protection glasses supplied with the ultraviolet (UV) lamp should be used to protect eyesight from harm.
    NOTE: The air conditioning (A/C) system has an R-134a leak trace dye wafer incorporated into the desiccant bag. The exact location of leaks can be pinpointed by the bright yellow/green glow of the tracer dye. Since more than one leak may exist, always inspect each component. If it is necessary to add dye (due to a severe leakage for example) use proprietary tracer dye injection equipment.
  2. Check all components, fittings and lines of the A/C system.
  3. Carry out the repair. For additional information, refer to: Climate Control System .
  4. After the leak is repaired, remove any traces of leak trace dye with a general purpose oil solvent.
  5. Check the A/C system for correct operation.
  6. Verify the repair by operating the system for a short time and inspecting with the (UV) lamp.