Pinpoint Test I: Memory Seat Bolster Inflate Tests
WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
TEST CONDITIONS
DETAILS/RESULTS/ACTIONS
- I1: MEMORY SEAT BOLSTER INFLATE TEST 1
- Using the Jaguar Land Rover approved diagnostic equipment, perform routine - On Demand Self Test
- Using the Jaguar Land Rover approved diagnostic equipment, check the relevant seat module for related DTCs and refer to the relevant DTC index
Are any relevant DTCs set?
- Yes : Perform the relevant corrective action
- No : GO to I2.
- I2: MEMORY SEAT BOLSTER INFLATE TEST 2 NOTE:
- Circuit reference - VBATT -
- The bolster inflate circuit current specification is 1.05A ± 10%.
- Connect an inductive ammeter to the seat switchpack power circuit
- Set the ignition to on
- Operate the seat switchpack bolster inflate switch
Is the measured current less than specification?
- Yes : GO to I3.
- No : Check the lumbar/bolster pump hose and the bolster air cell hoses for blockages/leaks
- I3: MEMORY SEAT BOLSTER INFLATE TEST 3 NOTE: Do not disconnect the electrical connector during this step; the seat switchpack is removed for access to the wiring harness only.
- Refer to the relevant section of the service information and remove the seat switchpack
- Set a multimeter to measure voltage
- Using the multimeter, measure and record the battery voltage (reference voltage)NOTE: Circuit reference - BOLSTER INF/GND -
- Connect the multimeter across the seat switchpack bolster inflate terminal and the ground terminal
- Set the ignition to on
- Operate the seat switchpack bolster inflate switch
Is the measured voltage less than battery voltage?
- Yes : GO to Pinpoint Test A .
- No
: Refer to the applicable System Wiring Diagram(s) and check the bolster inflate circuit for short circuit to ground, short circuit to power, open circuit, high resistanceNOTE: Some DTCs can only be set if the fault is detected during the On Demand Self Test routine.NOTE: The battery support unit must be connected during this test to ensure that the power supply is stable.