Pinpoint Test B: 4-Way Lumbar And Bolster Inflate Tests
WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
TEST CONDITIONS
DETAILS/RESULTS/ACTIONS
- B1: 4-WAY LUMBAR AND BOLSTER INFLATE TEST 1
- Set the ignition to on
- Operate the seat switchpack lumbar forward switch
- Listen for the lumbar air pump operating
Was the lumber air pump operation audible?
- Yes : GO to B2.
- No : GO to B3.
- B2: 4-WAY LUMBAR AND BOLSTER INFLATE TEST 2 NOTE: The battery support unit must be connected during this test to ensure that the power supply is stable.NOTE:
- Circuit reference - VBATT -
- The 4-way lumbar forward circuit current specification is 1.55A ± 10%.
- Connect an inductive ammeter to the seat switchpack power circuit
- Set the ignition to on
- Operate the seat switchpack lumbar forward switch.
Is the measured current greater than specification?
- Yes : Check the lumbar air pump hose for blockages.
- No : Check the lumbar air pump hoses for leaks.
- B3: 4-WAY LUMBAR AND BOLSTER INFLATE TEST 3 NOTE: Do not disconnect the electrical connector during this step; the seat switchpack is removed for access to the wiring harness only.
- Refer to the relevant service information and remove the seat switchpack.
- Set a multimeter to measure voltage.
- Using the multimeter, measure and record the battery voltage (reference voltage).NOTE: Circuit reference - LUMBAR PUMP/GND -
- Connect the multimeter across the seat switchpack lumbar pump terminal and the ground terminal.
- Set the ignition to on.
- Operate the seat switchpack lumbar forward switch.
Is the measured voltage less than battery voltage?
- Yes : GO to Pinpoint Test A .
- No : Refer to the applicable System Wiring Diagram(s) and check the lumbar air pump circuit for short circuit to ground, short circuit to power, open circuit, high resistance
NOTE:- When the seat switchpack lumbar forward switch is operated, the lumbar upper and lower inflate solenoids are energised.
- The battery support unit must be connected during this test to ensure that the power supply is stable.