Fault Diagnosis
WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
If there is a fault with the active grille air shutter, the 'Engine Over Temperature' warning is displayed in the Instrument Cluster (IC) message center. For each fault, a flag is set and after a calibrated de-bounce time, a DTC is stored in the PCM.
The following faults can be detected:
- Mechanical blockage fault - Motor encounters too much resistance and stalls. The maximum Torque is 0.7 - 0.8 Nm. Once blocked, the motor will try to recalibrate up to maximum number of attempts as described in the calibration section.
- Calibration failed fault - Fault is stored if all calibration attempts have failed in that drive cycle.
- Electrical fault - Motor reports an internal electrical fault.
- Supply voltage fault - Motor supply voltage falls outside the range 7.5 V - 17.5 V.
- Thermal shutdown fault - Motor circuits exceed their inbuilt temperature threshold.
- Disconnect fault - Linkage between the motor and the vanes becomes disconnected.
- Local Interconnect Network (LIN) Bus communication fault and Node detection fault - A fault with the motor, its signal wire or its supply that causes a breakdown in signals to the PCM. If the motor is still operational and only the signal wire has a short circuit/open circuit, then the motor will fail safe fully open after 10 seconds of not receiving a signal.