Home >> Jaguar >> 2019 >> XJR575 >> Repair and Diagnosis >> External Pages >> Different car >> Section 147 (Electronic Engine Controls - V6 S/C 3.0L Petrol -- XJ/X351) >> Electronic Engine Controls - V6 S/C 3.0L Petrol (G1514894) >> Diagnosis And Testing >> Electronic Engine Controls DTC: Heated Oxygen Sensors (HO2S) >> Heated Oxygen Sensor DATALOGGER Signals

Heated Oxygen Sensor DATALOGGER Signals

WARNING: This page is about a different car, the 2019 Jaguar XJ and 2018 Jaguar XJ. However, it is still accessible from the selected car via links, so may be relevant.
PID DESCRIPTION ACTION
BANK 1 
Datalogger signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 1 sensor 1 
0x03A1 Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 1 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a duty cycle displayed in % varying between limits
0xF434 Oxygen Sensor Current Bank 1 sensor 1 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in mA varying between limits
Datalogger signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 1 sensor 2 
0x03A2 Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 2 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF415 Oxygen Sensor Output Voltage Bank 1 - sensor 2 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits
Datalogger signal for Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 1 sensor 3 
0x03A3 Oxygen sensor heater duty cycle - Bank 1 sensor 3 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF416 Oxygen Sensor Output Voltage Bank 1 - sensor 3 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits
BANK 2 
Datalogger signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 2 sensor 1 
0x03A4 Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 1 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a duty cycle displayed in % varying between limits
0xF438 Oxygen Sensor Current Bank 2 sensor 1 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in mA varying between limits
Datalogger signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 2 sensor 2 
0x03A5 Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 2 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF419 Oxygen Sensor Output Voltage Bank 2 - sensor 2 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits
Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 2 sensor 3 
0x03A6 Oxygen sensor heater duty cycle - Bank 2 sensor 3 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF41A Oxygen Sensor Output Voltage Bank 2 - sensor 3 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits