Home >> Jaguar >> 2019 >> XF S >> Repair and Diagnosis >> External Pages >> Different car >> Section 211 (Electronic Engine Controls - INGENIUM I4 2.0L Diesel -- XE/(760)) >> Electronic Engine Controls - INGENIUM I4 2.0L Diesel (G1817213) >> Diagnosis And Testing >> Electronic Engine Controls >> Drive Cycle: Particulate Matter (Pm) Sensor Monitors >> Test Procedure

Test Procedure

WARNING: This page is about a different car, the 2019 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
  1. Using the Jaguar Land Rover approved diagnostic equipment, perform routine - OBD II Readiness Tests.
  2. Drive the vehicle steadily at a speed of approximately 50 mph (80 km/h) for a minimum of 10 minutes.
    NOTE: If a gear shift occurs during this step, the step must be repeated. To avoid gear shifts, manual gear selections or 3rd or 4th gear may be used.
  3. Perform three or more sharp accelerations, followed by fuel cut off:
    1. Drive the vehicle at a speed of approximately 55 mph (88 km/h) and select 4th gear.
    2. Accelerate gently and then release the accelerator pedal to trigger fuel cut off. Do not press the accelerator pedal or brake pedal for a duration of 5 seconds.
  4. Using the Jaguar Land Rover approved diagnostic equipment, check the readiness status of the exhaust gas sensors monitor.