General Procedures
| 82.30.30 | AIR CONDITIONING - RECOVER, RECYCLE AND RECHARGE SYSTEM | ALL DERIVATIVES | 0.6 | USED WITHINS |
-
Refrigerant recovery.
Remove the dust covers from the high and low pressure connections.
- Connect the high and low pressure lines to the appropriate connections.
-
Following the manufacturer's instructions, recover the refrigerant from the A/C system.
- Make sure that all openings are sealed. Use new blanking caps.
- Always follow the health and safety precautions when handling the refrigerant R-134a or R-1234yf.
- Collect the refrigerant in specialist equipment and reuse.
-
Disconnect the high and low pressure connections.
- Vacuum procedure.
- Connect the high and low pressure lines to the appropriate connections.
- Following the manufacturer's instructions, vacuum the A/C system.
- Filling.
-
Recharging
-
Make sure the correct amount of oil is added to the A/C system before or during recharging.
-
Recharge the A/C system to the correct specification.
- Disconnect the high and low pressure connections.
Install and firmly tighten the caps that cover the high and low pressure connections.
WARNING:
Servicing must be carried out by personnel familiar with both vehicle system and the charging and testing equipment. All operations must be carried out in a well ventilated area away from open flame and heat sources.
CAUTION:
If equipped with refrigerant checking devices, it is recommended that the system is tested prior to recovery. Air conditioning (A/C) systems filled with incorrect refrigerant can cause damage to vehicles system and the equipment used to service them.
WARNING:
Refrigerant must always be recycled before re-use to ensure that the purity of the refrigerant is high enough for safe use in the A/C system. Recycling should always be carried out with equipment which is design certified for compliance with SAE J2099 and SAE J2788. Other equipment may not recycle refrigerant to the required level of purity. R-134a or R-1234yf Refrigerant Recover Recycling Recharging stations must not be used with any other type of refrigerant. Refrigerant R-134a or R-1234yf from domestic and commercial sources must not be used in motor vehicles A/C systems.
CAUTION:
NOTE:
The receiver drier need only be changed under the following circumstances: There is dirt in the refrigerant circuit (eg. compressor seizure), the system is leaking and refrigerant has been lost to atmosphere, or the refrigerant circuit has been open more than 24 hours, due to repair.
CAUTION:
The system must be evacuated immediately before recharging commences. Delay between evacuation and recharging is not permitted
NOTE:
Refer to specifications
NOTE:
Refer to specifications