LEMON Manuals: Even more car manuals for everyone
Home >> Jaguar >> 2014 >> XK Base, 2D Coupe >> Repair and Diagnosis >> External Pages >> Different car >> Section 91 (Electronic Engine Controls - V8 S/C 5.0L Petrol -- XK/X150) >> Electronic Engine Controls - V8 S/C 5.0L Petrol >> Electronic Engine Controls DTC: Heated Oxygen Sensors (Ho2S) >> Diagnosis And Testing >> Heated Oxygen Sensor Datalogger Signals

Heated Oxygen Sensor Datalogger Signals

WARNING: This page does not describe the selected car, but rather 10 other vehicles, including the 2015 Jaguar XKR-S, 2015 Jaguar XKR, 2014 Jaguar XKR-S, 2014 Jaguar XKR, and 2013 Jaguar XKR-S. However, it is still accessible from the selected car via links, so may be relevant.
PID DESCRIPTION ACTION
BANK 1 
Datalogger signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 1 sensor 1 
0x03A1 Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 1 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a duty cycle displayed in % varying between limits
0xF434 Oxygen Sensor Current Bank 1 sensor 1 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in mA varying between limits
Datalogger signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 1 sensor 2 
0x03A2 Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 2 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF415 Oxygen Sensor Output Voltage Bank 1 - sensor 2 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits
Datalogger signal for Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 1 sensor 3 
0x03A3 Oxygen sensor heater duty cycle - Bank 1 sensor 3 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF416 Oxygen Sensor Output Voltage Bank 1 - sensor 3 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits
BANK 2 
Datalogger signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 2 sensor 1 
0x03A4 Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 1 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a duty cycle displayed in % varying between limits
0xF438 Oxygen Sensor Current Bank 2 sensor 1 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in mA varying between limits
Datalogger signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 2 sensor 2 
0x03A5 Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 2 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF419 Oxygen Sensor Output Voltage Bank 2 - sensor 2 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits
Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 2 sensor 3 
0x03A6 Oxygen sensor heater duty cycle - Bank 2 sensor 3 Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF41A Oxygen Sensor Output Voltage Bank 2 - sensor 3 Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits