Home >> Jaguar >> 2014 >> XK Base, 2D Coupe >> Repair and Diagnosis >> External Pages >> Different car >> Section 34 (Battery & Charging System - General Information) >> Battery And Charging System - General Information >> Description And Operation >> Battery Care Requirements >> 4. Battery Care Requirements >> 4.6 Battery Test Process

4.6 Battery Test Process

WARNING: This page is about a different car, the 2011 Jaguar XKR, 2011 Jaguar XK, 2010 Jaguar XKR, and 2010 Jaguar XK. However, it is still accessible from the selected car via links, so may be relevant.

It is recommended that this test is conducted at least 24 hours after the vehicle engine has been run or the battery charged to avoid the need of surface charge removal. If time constraints make this unacceptable then the surface charge must be removed.

Surface Charge Removal 

A vehicle which has had its battery charged or been driven in a 24 hour period before the test, must have its surface charge removed.

Battery Test 

The battery may be tested either on a bench or on the vehicle.

The battery condition must be checked in accordance with the battery test process utilizing an appropriate tester as outlined in the equipment section (Section 5) of this procedure. 

NOTE: The midtronics code must be recorded on the form.

Any actions must be carried out in accordance with the table shown in the determining battery condition section (Section 6) of this procedure.  The details must be recorded on the New Vehicle Storage Form which is part of the new vehicle storage document.

CAUTION: DO NOT connect the tester to any other circuit or chassis point other than the battery negative terminal.