Occupant Classification System
WARNING: This page is about a different car, the 2011 Jaguar XKR, 2011 Jaguar XK, 2010 Jaguar XKR, and 2010 Jaguar XK. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:
When probing connectors to take measurements in the course of the pinpoint tests, use the adaptor kit, part number 3548-1358-00.
NOTE:
If the control module is suspect and the vehicle remains under manufacturer warranty, refer to the Warranty Policy and Procedures manual (section B1.2), or determine if any prior approval program is in operation, prior to the installation of a new module.
NOTE:
Generic scan tools may not read the codes listed, or may read only five digit codes. Match the five digits from the scan tool to the first five digits of the seven digit code listed to identify the fault (the last two digits give additional information read by the manufacturer approved diagnostic system).
NOTE:
When performing electrical voltage or resistance tests, always use a digital multimeter (DMM) accurate to three decimal places, and with an up-to-date calibration certificate. When testing resistance, always take the resistance of the DMM leads into account.
NOTE:
Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.
NOTE:
Inspect connectors for signs of water ingress, and pins for damage and/or corrosion.
NOTE:
If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern may be the cause. Always check for loose connections and corroded terminals.
| DTC | Description | Possible Cause | Action |
|---|---|---|---|
| B1193-53 | Crash Event Storage Full and Locked - De-activated |
|
Clear DTC, cycle ignition and re-test. If DTC remains check for other DTCs and refer to relevant DTC Index |
| B1A54-01 | Occupant Belt Tension Sensor - General electrical failure |
|
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly |
| B1A54-02 | Occupant Belt Tension Sensor - General signal failure |
|
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly |
| B1A54-11 | Occupant Belt Tension Sensor - Circuit short to ground |
|
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly |
| B1A54-12 | Occupant Belt Tension Sensor - Circuit short to battery |
|
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly |
| B1A54-13 | Occupant Belt Tension Sensor - Circuit open |
|
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly |
| B1A62-02 | Pressure Sensor - General signal failure |
|
Refer to the electrical guide and check the occupant pressure sensor circuit. Renew the sensor |
| B1A62-11 | Pressure Sensor - Circuit short to ground |
|
Refer to the electrical guide and check the occupant pressure sensor circuit. Renew the Control module. Refer to the warranty policy and procedures manual if a module is suspect |
| B1A62-12 | Pressure Sensor - Circuit short to battery |
|
Refer to the electrical guide and check the occupant pressure sensor circuit. Renew the Control module. Refer to the warranty policy and procedures manual if a module is suspect |
| B1A62-7A | Pressure Sensor - Fluid leak or seal failure |
|
Clear the DTC and retest. If the problem persists, renew the restraints Control module. Refer to the warranty policy and procedures manual if a module is suspect |
| B1A62-7B | Pressure Sensor - Low fluid level |
|
Renew the occupant pressure sensor |
| U0001-00 | High Speed CAN Communication Bus - No sub type information |
|
Refer to the electrical circuit diagrams and check the power and ground connections to the module. Using the manufacturer approved diagnostic system, complete a CAN network integrity test. Refer to the electrical circuit diagrams and check the CAN network |
| U0151-00 | Lost Communication With Restraints Control Module - No sub type information |
|
Refer to the electrical circuit diagrams and check the power and ground connections to the module. Using the manufacturer approved diagnostic system, complete a CAN network integrity test. Refer to the electrical circuit diagrams and check the CAN network between the Restraints Control Module and Safety Belt System |
| U0300-00 | Internal Control Module Software Incompatibility - No sub type information |
|
Check correct occupancy classification system module is installed for vehicle specification. Check for other DTCs and refer to relevant DTC Index. Configure the module using the approved diagnostic system |
| U3000-04 | Control Module - System internal failures |
|
Renew the occupancy classification system module. Refer to the warranty policy and procedures manual if a module is suspect |
| U3000-51 | Control Module - Not programmed |
|
Configure the module using the approved diagnostic system, check and repair Restraints Control Module circuit as required |
| U3000-54 | Control module - Missing calibration |
|
Configure the module using the approved diagnostic system |
| U3003-16 | Battery Voltage - Circuit voltage below threshold |
|
Check vehicle battery and charging system. Refer to the relevant section in the service information |
| U3003-17 | Battery Voltage - Circuit voltage above threshold |
|
Check vehicle battery and charging system. Refer to the relevant section in the service information. Refer to the electrical circuit diagrams and check the power supply circuits to the module |