Occupant Classification System

WARNING: This page is about a different car, the 2011 Jaguar XKR, 2011 Jaguar XK, 2010 Jaguar XKR, and 2010 Jaguar XK. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: When probing connectors to take measurements in the course of the pinpoint tests, use the adaptor kit, part number 3548-1358-00.
NOTE: If the control module is suspect and the vehicle remains under manufacturer warranty, refer to the Warranty Policy and Procedures manual (section B1.2), or determine if any prior approval program is in operation, prior to the installation of a new module.
NOTE: Generic scan tools may not read the codes listed, or may read only five digit codes. Match the five digits from the scan tool to the first five digits of the seven digit code listed to identify the fault (the last two digits give additional information read by the manufacturer approved diagnostic system).
NOTE: When performing electrical voltage or resistance tests, always use a digital multimeter (DMM) accurate to three decimal places, and with an up-to-date calibration certificate. When testing resistance, always take the resistance of the DMM leads into account.
NOTE: Check and rectify basic faults before beginning diagnostic routines involving pinpoint tests.
NOTE: Inspect connectors for signs of water ingress, and pins for damage and/or corrosion.
NOTE: If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern may be the cause. Always check for loose connections and corroded terminals.
DTC Description Possible Cause Action
B1193-53 Crash Event Storage Full and Locked - De-activated
  • Event information, system deactivated
  • A collision event has occurred
  • Maximum number of events stored
Clear DTC, cycle ignition and re-test. If DTC remains check for other DTCs and refer to relevant DTC Index
B1A54-01 Occupant Belt Tension Sensor - General electrical failure
  • General signal failure
  • Belt tension sensor has jammed for 3 seconds or longer
  • Belt tension sensor failure
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly
B1A54-02 Occupant Belt Tension Sensor - General signal failure
  • General signal failure
  • Pressure sensor signal short circuit to belt tension sensor signal at initialization
  • Belt tension sensor failure
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly
B1A54-11 Occupant Belt Tension Sensor - Circuit short to ground
  • Pressure sensor circuit short circuit to ground for 3 seconds or longer
  • Belt tension sensor failure
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly
B1A54-12 Occupant Belt Tension Sensor - Circuit short to battery
  • Pressure sensor circuit short circuit to power for 3 seconds or longer
  • Belt tension sensor failure
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly
B1A54-13 Occupant Belt Tension Sensor - Circuit open
  • Pressure sensor circuit open circuit for 3 seconds or longer
  • Belt tension sensor failure
Refer to the electrical circuit diagrams and check belt tension sensor circuit. Renew the safety belt buckle assembly
B1A62-02 Pressure Sensor - General signal failure
  • Occupant pressure sensor general signal failure
  • Occupant pressure sensor signal short circuit to belt tension sensor signal at initialization
  • Occupant pressure sensor failure
Refer to the electrical guide and check the occupant pressure sensor circuit. Renew the sensor
B1A62-11 Pressure Sensor - Circuit short to ground
  • Occupant pressure sensor signal short circuit to ground
  • Restraints Control module fault
Refer to the electrical guide and check the occupant pressure sensor circuit. Renew the Control module. Refer to the warranty policy and procedures manual if a module is suspect
B1A62-12 Pressure Sensor - Circuit short to battery
  • Occupant pressure sensor signal short circuit to power
  • Restraints Control module fault
Refer to the electrical guide and check the occupant pressure sensor circuit. Renew the Control module. Refer to the warranty policy and procedures manual if a module is suspect
B1A62-7A Pressure Sensor - Fluid leak or seal failure
  • Occupant pressure sensor fluid leak or seal failure
  • Restraints Control module fault
Clear the DTC and retest. If the problem persists, renew the restraints Control module. Refer to the warranty policy and procedures manual if a module is suspect
B1A62-7B Pressure Sensor - Low fluid level
  • Occupant pressure sensor bladder low fluid level
Renew the occupant pressure sensor
U0001-00 High Speed CAN Communication Bus - No sub type information
  • Bus off
  • CAN High and CAN Low are shorted together
Refer to the electrical circuit diagrams and check the power and ground connections to the module. Using the manufacturer approved diagnostic system, complete a CAN network integrity test. Refer to the electrical circuit diagrams and check the CAN network
U0151-00 Lost Communication With Restraints Control Module - No sub type information
  • Lost communications - CAN or hardwired
  • Restraints Control module fault
Refer to the electrical circuit diagrams and check the power and ground connections to the module. Using the manufacturer approved diagnostic system, complete a CAN network integrity test. Refer to the electrical circuit diagrams and check the CAN network between the Restraints Control Module and Safety Belt System
U0300-00 Internal Control Module Software Incompatibility - No sub type information
  • Module is not configured correctly
  • Master config ID doesn't correspond
Check correct occupancy classification system module is installed for vehicle specification. Check for other DTCs and refer to relevant DTC Index. Configure the module using the approved diagnostic system
U3000-04 Control Module - System internal failures
  • Restraints Control module fault
Renew the occupancy classification system module. Refer to the warranty policy and procedures manual if a module is suspect
U3000-51 Control Module - Not programmed
  • Restraints Control Module not configured, circuit fault
Configure the module using the approved diagnostic system, check and repair Restraints Control Module circuit as required
U3000-54 Control module - Missing calibration
  • Missing calibration, empty seat calibration required
Configure the module using the approved diagnostic system
U3003-16 Battery Voltage - Circuit voltage below threshold
  • Battery voltage below threshold (8 volts)
Check vehicle battery and charging system. Refer to the relevant section in the service information
U3003-17 Battery Voltage - Circuit voltage above threshold
  • Battery voltage above threshold (18 volts)
Check vehicle battery and charging system. Refer to the relevant section in the service information. Refer to the electrical circuit diagrams and check the power supply circuits to the module