LEMON Manuals: Even more car manuals for everyone
Home >> Jaguar >> 2014 >> XK Base, 2D Coupe >> Repair and Diagnosis >> External Pages >> Different car >> Section 14 (Electronic Engine Controls (V8 5.0L Petrol)) >> Electronic Engine Controls (V8 5.0L Petrol) >> Description And Operation >> Electronic Engine Controls >> Heated Oxygen Sensors

Heated Oxygen Sensors

WARNING: This page is about a different car, the 2011 Jaguar XK and 2010 Jaguar XK. However, it is still accessible from the selected car via links, so may be relevant.
GJ0023065Courtesy of JAGUAR CARS, INC.
Item Number Description
A Upstream heated oxygen sensor
B Downstream heated oxygen sensor

The heated oxygen sensors allow the engine control module (ECM) to measure the oxygen content of the exhaust gases, for closed loop control of the fuel: air mixture and for catalytic converter monitoring.

An upstream heated oxygen sensor is installed in the outlet of each exhaust manifold, which enables independent control of the fuel: air mixture for each cylinder bank. A downstream heated oxygen sensor is installed in each catalytic converter, which enables the performance of the catalytic converters to be monitored.

Oxygen sensors need to operate at high temperatures in order to function correctly. To achieve the high temperatures required, the sensors are fitted with heater elements that are controlled by a pulse width modulation (PWM) signal from the engine control module (ECM). The heater elements are operated immediately after each engine start and during low load conditions when the temperature of the exhaust gases is insufficient to maintain the required sensor temperature. The pulse width modulation (PWM) duty cycle is carefully controlled to prevent thermal shock to cold sensors. A non-functioning heater delays the sensor's readiness for closed loop control and increases emissions.

The upstream heated oxygen sensors produce a constant voltage, with a variable current that is proportional to the lambda ratio. The downstream heated oxygen sensors produce an output voltage dependent on the ratio of the exhaust gas oxygen to the ambient oxygen.

The heated oxygen sensors age with mileage, increasing their response time to switch from rich to lean and lean to rich. This increase in response time influences the engine control module (ECM) closed loop control and leads to progressively increased emissions. Measuring the period of rich to lean and lean to rich switching monitors the response rate of the upstream sensors.

Diagnosis of electrical faults is continually monitored in both the upstream and downstream sensors. This is achieved by checking the signal against maximum and minimum threshold, for open and short circuit conditions.

If a heated oxygen sensor fails:

With a failed heated oxygen sensor, the engine will suffer from unstable operation and reduced performance.