DTC B10A6-11: Main Light Switch - Circuit short to ground: Action
- Refer to applicable SYSTEM WIRING DIAGRAM(S) and check the high beam switch circuits for short circuit to ground. Repair wiring harness as required. Clear DTC and retest
- If no circuit faults are present, check and install new switch as required. Clear DTC and retest