Heated Oxygen Sensor Datalogger Signals
WARNING: This page is about a different car, the 2015 Jaguar XK, 2014 Jaguar XK, 2013 Jaguar XK, and 2012 Jaguar XK. However, it is still accessible from the selected car via links, so may be relevant.
| PID | DESCRIPTION | ACTION |
|---|---|---|
| BANK 1 | ||
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 1 sensor 1 | ||
| 0x03A1 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 1 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a duty cycle displayed in % varying between limits |
| 0xF434 | Oxygen Sensor Current Bank 1 sensor 1 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in mA varying between limits |
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 1 sensor 2 | ||
| 0x03A2 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 2 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF415 | Oxygen Sensor Output Voltage Bank 1 - sensor 2 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits |
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 1 sensor 3 | ||
| 0x03A3 | Oxygen sensor heater duty cycle - Bank 1 sensor 3 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF416 | Oxygen Sensor Output Voltage Bank 1 - sensor 3 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits |
| BANK 2 | ||
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 2 sensor 1 | ||
| 0x03A4 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 1 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a duty cycle displayed in % varying between limits |
| 0xF438 | Oxygen Sensor Current Bank 2 sensor 1 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in mA varying between limits |
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 2 sensor 2 | ||
| 0x03A5 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 2 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF419 | Oxygen Sensor Output Voltage Bank 2 - sensor 2 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits |
| Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 2 sensor 3 | ||
| 0x03A6 | Oxygen sensor heater duty cycle - Bank 2 sensor 3 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF41A | Oxygen Sensor Output Voltage Bank 2 - sensor 3 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits |