Headlamp Washers
The headlamp washers are only active when the headlamps and ignition are switched on. If the washer reservoir fluid level becomes low, the instrument cluster sends a message, via the medium speed CAN bus, to the CJB, which suspends headlamp wash operation to preserve washer fluid in the reservoir.
With the ignition and lights on, headlamp wash is activated on the first operation of the wiper column control switch in the wash/wipe position.
The CJB monitors the operation of the wash/wipe switch and maintains a counter to restrict headlamp washer operation to every fourth operation of the wash/wipe switch in conjunction with a 10-minute timer. The timer prevents a second operation of the headlamp washers within a 10-minute period. Should the washer switch be activated for more than 4 programmed wipe requests during the 10-minute period, the headlamp washer will remain disabled. Only the next consecutive programmed wipe request, after the 10-minute timer has expired, will the headlamp washers be enabled. The counter and timer are reset when the ignition is set in the 'Off' mode or the light switch is turned from OFF back to ON within the same ignition cycle.
When headlamp wash is active, the CJB energizes the washer pump twice per cycle. The headlamp washer pump is powered for 2 x 800 ms periods.