G295394t11: CHECK THE EPB MOTOR + CIRCUIT FOR OPEN CIRCUIT
- Disconnect the battery negative terminal.
- Disconnect the EPB motor electrical connector, CV07.
- Disconnect the EPB control module electrical connector, CR50.
- Measure the resistance between CV07, pin 01 (RW) and CR50, pin 03 (RW).
- Is the resistance greater than 5 ohms?
- Yes: REPAIR the high resistance circuit. For additional information, refer to the wiring diagrams. CLEAR the DTC. TEST the system for normal operation.
- No: GO to Pinpoint Test G295394T12 .