G256924t20: CHECK THE LEFT-HAND FRONT AIR SPRING DRIVE CIRCUIT FOR SHORT TO B+
- Disconnect the left-hand front air spring electrical connector, EC47.
- Measure the voltage between EC47, pin 02 (BO) and GROUND.
- Is the voltage greater than 3 volts?
- -> Yes: REPAIR the short circuit. For additional information, refer to the appropriate SYSTEM WIRING DIAGRAMS article. CLEAR the DTC. TEST the system for normal operation.
- -> No: Go to Pinpoint G256924t21: CHECK THE LEFT-HAND FRONT AIR SPRING DRIVE CIRCUIT FOR SHORT TO GROUND .