LEMON Manuals: Even more car manuals for everyone
Home >> Isuzu >> 2007 >> i-290 LS, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 13 (HVAC System - Automatic) >> Diagnostic Information and Procedures >> Scan Tool Data List

Scan Tool Data List

WARNING: This page is about a different car, the 2007 Cadillac DTS. However, it is still accessible from the selected car via links, so may be relevant.
HVAC Control Module Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C Evap. Temperature Sensor HVAC Sensors °C/°F Varies
A/C High Side Pressure Sensor HVAC Sensors kPa/psi Varies
Ambient Air Temp. Sensor HVAC Sensors, HVAC System Data, Open/Short Data °C/°F Varies
Aux. Mode Door Actual HVAC Door Positions Counts Varies
Aux. Mode Door Command HVAC Door Positions Counts Varies
Aux. Temp Dr. Position HVAC Door Positions Counts Varies
Aux. Temp Dr. Motor Command HVAC Door Positions Counts Varies
Blower Motor Relay Cmd. HVAC System Data On/Off On
Blower Motor Speed command HVAC System Data % Varies
Coolant Temperature HVAC Sensors, HVAC System Data °C/°F Varies
Driver Temp. Dr. Motor Commanded HVAC Door Positions Counts Varies
Driver Temp. Dr. Position HVAC Door Positions Counts Varies
Inside Air Temp. Sensor HVAC Sensors, HVAC System Data, Open/Short Data °C/°F Varies
Left Sunload Sensor HVAC Sensors, Open/Short Data Counts Varies
Mode Dr. Motor Command HVAC Door Positions Counts Varies
Mode Door Position HVAC Door Positions Counts Varies
Psgr. Temp. Dr. Motor Command HVAC Door Positions Counts Varies
Psgr. Temp. Dr. Position HVAC Door Positions Counts Varies
Rear Defrost State HVAC System Data On/Off Off
Recirculation Dr. Motor Command HVAC Door Positions Counts Varies
Recirculation Dr. Position HVAC Door Positions Counts Varies
Right Sunload Sensor HVAC Sensors, Open/Short Data Counts Varies
Vehicle Speed HVAC System Data Km/h/mph Varies
Water Pump Relay HVAC System Data On/Off On
Aux. HVAC Control Module Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
Aux. Blower Motor PWM Data Display % Varies
ECM Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C Request Signal Cooling/HVAC Data Yes/No Yes
A/C Relay Command Cooling/HVAC Data On/Off On
A/C Relay Circuit Status Cooling/HVAC Data Incomplete, Short Gnd, Open Short to B+ Incomplete
A/C High Side Pressure Sensor Cooling/HVAC Data Volts Varies
A/C High Side Pressure Sensor Cooling/HVAC Data kPa/Psi 629-845 kPa (85-120 psi)
A/C Off For WOT Cooling/HVAC Data Yes/No No
A/C Pressure Disable Cooling/HVAC Data Yes/No No
A/C Disengage 1 History Cooling/HVAC Data None, A/C Pressure, Engine Speed, Battery Voltage, Stall Prevention, RPM Unstable, WOT, Launch Performance, Coolant Hot None
A/C Disengage 2 History Cooling/HVAC Data None, A/C Pressure, Engine Speed, Battery Voltage, Stall Prevention, RPM Unstable, WOT, Launch Performance, Coolant Hot None
A/C Disengage 3 History Cooling/HVAC Data None, A/C Pressure, Engine Speed, Battery Voltage, Stall Prevention, RPM Unstable, WOT, Launch Performance, Coolant Hot None
A/C Disengage 4 History Cooling/HVAC Data None, A/C Pressure, Engine Speed, Battery Voltage, Stall Prevention, RPM Unstable, WOT, Launch Performance, Coolant Hot None
A/C Disengage 5 History Cooling/HVAC Data None, A/C Pressure, Engine Speed, Battery Voltage, Stall Prevention, RPM Unstable, WOT, Launch Performance, Coolant Hot None
A/C Disengage 6 History Cooling/HVAC Data None, A/C Pressure, Engine Speed, Battery Voltage, Stall Prevention, RPM Unstable, WOT, Launch Performance, Coolant Hot None
A/C Disengage 7 History Cooling/HVAC Data None, A/C Pressure, Engine Speed, Battery Voltage, Stall Prevention, RPM Unstable, WOT, Launch Performance, Coolant Hot None
A/C Disengage 8 History Cooling/HVAC Data None, A/C Pressure, Engine Speed, Battery Voltage, Stall Prevention, RPM Unstable, WOT, Launch Performance, Coolant Hot None
ECT Sensor Cooling/HVAC Data °C/°F 92°C (197°F)