Diagnostic Aids
WARNING: This page is about a different car, the 2007 Cadillac DTS. However, it is still accessible from the selected car via links, so may be relevant.
- If the control A circuit of the recirculation actuator is shorted to ground, the following conditions will occur.
- The recirculation actuator will operate properly when recirculation is requested.
- The recirculation actuator will continually modulate between the outside air and recirculation positions when outside air is requested.
- If the control B circuit of the recirculation actuator is shorted to ground, the following conditions will occur.
- The recirculation actuator will operate properly when outside air is requested.
- The recirculation actuator will continually modulate between the outside air and recirculation positions when recirculation is requested.
- Inspect the recirculation door and the recirculation actuator for the following conditions:
- A misaligned recirculation actuator-Refer to Recirculation Actuator Replacement .
- Broken or binding linkages
- A broken or binding recirculation door
- An obstruction that prevents the recirculation door from operating within its full range of motion
- Missing seals to the recirculation door
- Misaligned seals to the recirculation door
Air Recirculation Malfunction
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. |
|||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle |
| 2 |
|
Go to Diagnostic Aids | Go to Step 3 |
| 3 |
|
Go to Diagnostic Aids | Go to Step 4 |
| 4 |
|
Go to Step 12 | Go to Step 5 |
| 5 |
|
Go to Step 6 | Go to Step 13 |
| 6 |
|
Go to Step 7 | Go to Step 8 |
| 7 |
|
Go to Step 10 | Go to Step 9 |
| 8 | Test the control A circuit of the recirculation actuator for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? |
Go to Step 16 | Go to Step 12 |
| 9 | Test the control B circuit of the recirculation actuator for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? |
Go to Step 16 | Go to Step 12 |
| 10 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? |
Go to Step 16 | Go to Step 11 |
| 11 | Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 16 | Go to Step 14 |
| 12 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
. Did you find and correct the condition? |
Go to Step 16 | Go to Step 15 |
| 13 | Repair the ignition 3 voltage circuit of the recirculation actuator. Refer to Wiring Repairs
. Did you complete the repair? |
Go to Step 16 | - |
| 14 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? |
Go to Step 16 | - |
| 15 | Replace the HVAC control module. Refer to Control Module References
for replacement, setup and programming. Did you complete the replacement? |
Go to Step 16 | - |
| 16 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |