Hazard Lamps Inoperative
Hazard Lamps Inoperative
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: Exterior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views |
|||
| 1 | Did you review the Exterior Lighting Systems Description and Operation and perform the necessary inspections? | Go to Step 2 | Go to Exterior Lighting Systems Description and Operation |
| 2 | Verify that the hazard lamps are inoperative. Do the hazard lamps operate normally? |
Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
| 3 | Do the turn signal lamps operate normally? | Go to Step 4 | Go to Symptoms - Lighting Systems |
| 4 |
|
Go to Step 6 | Go to Step 5 |
| 5 | Test the multifunction turn signal switch hazard switch signal circuit and ground circuit for an open or high resistance. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct a condition? |
Go to Step 10 | Go to Step 7 |
| 6 | Inspect for poor connections at the harness connector of the hazard/turn flasher. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct a condition? |
Go to Step 10 | Go to Step 8 |
| 7 | Inspect for poor connections at the harness connector of the multifunction turn signal switch. Refer to Circuit Testing
and Wiring Repairs
. Did you find and correct the condition? |
Go to Step 10 | Go to Step 9 |
| 8 | Replace the hazard/turn flasher. Refer to Hazard and Turn Signal Flasher Replacement . Did you complete the repair? |
Go to Step 10 | - |
| 9 | Replace the multifunction turn signal switch. Refer to Turn Signal Multifunction Switch Replacement
. Did you complete the repair? |
Go to Step 10 | - |
| 10 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |