Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the IPC.
- Ignition ON, verify that a test lamp illuminates between the ignition 1 voltage circuit and ground
- If the test lamp does not illuminate, repair the ignition 1 voltage circuit for an open/high resistance. If the ignition 1 voltage circuit fuse is open, also test the voltage circuit for a short to ground
- If all circuits test normal, test or replace the IPC.