BLOWER MOTOR RESISTOR REPLACEMENT - AUXILIARY

REMOVAL PROCEDURE
1. Remove the rear HVAC module assembly.




2. Disconnect the electrical connector from the blower motor control processor-auxiliary (3).
3. Remove the screws from the blower motor control processor-auxiliary (3).
4. Remove the blower motor control processor-auxiliary (3).
5. Remove the thermal gasket from the evaporator core-auxiliary surface.

INSTALLATION PROCEDURE
1. Install the thermal gasket to the blower motor control processor-auxiliary.




2. Install the blower motor control processor-auxiliary (3).
3. Install the screws to the blower motor control processor-auxiliary (3).

Tighten the screws to 2 N.m (18 lb in).

NOTE: Refer to Fastener Notice in Service Precautions.

4. Connect the electrical connector to the blower motor control processor-auxiliary (3).
5. Install the HVAC module-auxiliary.