AIR OUTLET DUCT REPLACEMENT - FLOOR, RH

REMOVAL PROCEDURE




1. Remove the HVAC module assembly.
2. Remove the floor air outlet duct retaining screws (2,3,4).
3. Remove the RH side floor air outlet duct (1).

INSTALLATION PROCEDURE




1. Install the floor air outlet duct (1) into position.
2. Install the floor air outlet duct retaining screws (2,3,4).

Tighten the screws to 1.9 N.m (17 lb in).

NOTE: Refer to Fastener Notice in Service Precautions.