DTC 35: EHCU Pump Valve & Valve Relay Circuit
Turn ignition off. Disconnect EHCU harness connector. Using DVOM, measure voltage between ground and EHCU harness connector terminal No. 14 (Yellow/Green wire). If battery voltage is present, replace EHCU. If battery voltage is not present, check condition of ABS fuses (20-amp and 40-amp), located in engine compartment fuse block. Also, check Yellow/Green wire between fuse and EHCU for an open or short to ground. Repair as necessary.