Horns Sound Continuously: Hombre
- Remove horn relay, located in Underhood Bussed Electrical Center (UBEC). If horns stop sounding, go to step 3). If horns do not stop sounding, go to next step.
- Repair short to voltage in Dark Green wire between horn relay and horn. See WIRING DIAGRAMS .
- Connect test light between horn relay cavity terminals No. 1 and 2 in UBEC. If test light comes on, go to step 5). If test light does not come on, go to next step.
- Replace horn relay. Recheck system operation.
- With test light still connected between horn relay cavity terminals No. 1 and 2 of UBEC, disconnect horn switches. If test light does not come on, go to next step. If test light comes on, go to step 7).
- Repair short to ground in Black wire between horn relay and horn switch. See WIRING DIAGRAMS .
- With test light still connected between horn relay cavity terminals No. 1 and 2 of UBEC, disconnect Body Control Module (BCM). See BODY CONTROL MODULES article. If test light does not come on, go to step 9). If test light comes on, go to next step.
- Repair short to ground in Black wire between horn relay, horn switch and body control module. See WIRING DIAGRAMS .