Fuel Gauge
- Disconnect battery negative cable. Remove instrument cluster. Refer to INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Using an ohmmeter, measure resistance between IGN and UNIT terminals. SeeFig 1 .
- Resistance should be about 103 ohms. Measure resistance between UNIT and GND terminals. SeeFig 1 . Resistance should be about 65 ohms. If resistance readings are not as specified, replace fuel gauge.