LEMON Manuals: Even more car manuals for everyone
Home >> Isuzu >> 1988 >> I-Mark LS >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Panel - Standard >> Component Testing >> Temperature Gauge >> With Turbocharger

With Turbocharger

Measure resistance between "IG" and "GND" terminals. Resistance should be 146.3 ohms. Measure resistance between "IG" and "TU" terminals. Resistance should be 60 ohms. SeeFig 1 .

Fig 1: Checking Temperature Gauge
G102978