LEMON Manuals: Even more car manuals for everyone
Home >> Isuzu >> 1985 >> I-Mark 4D Hatchback, Automatic >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Panel - Standard (Fwd) >> Component Testing >> Temperature Sending Unit

Temperature Sending Unit

Using hot water, warm-up sending unit to 122°F (50°C). Using an ohmmeter, check that resistance is about 226 ohms. At 239°F (115°C), resistance should be about 26 ohms.