P'UP & Trooper II
Connect ohmmeter to fuel tank sending unit. As float is moved, resistance reading should change smoothly. Check resistance at full position. Resistance should be 15-19 ohms. Resistance at half full position should be 41-50 ohms. Resistance at empty position should be 114-127 ohms. If readings are not correct, replace sending unit.