Connecting Rod Bearings
- After ensuring rod caps are marked for cylinder identification, remove rod caps. Use Plastigage method to check for proper clearance. Rod caps must be tightened to specification when measuring clearances.
- If not within limits, new bearings must be installed. Replacement bearings are available in standard, 0.010" (.25 mm), and 0.020" (.50 mm) undersize.