Temperature Setting Trimmer
DESCRIPTION
If the temperature felt by the customer is different from the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.
HOW TO SET
CONSULT Select "TEMP SET CORRECT" in "Work support" mode of "HVAC".
| Work support items | Display (°C) | Display (°F) |
|---|---|---|
| TEMP SET CORRECT | 3.0 | 6 |
| 2.5 | 5 | |
| 2.0 | 4 | |
| 1.5 | 3 | |
| 1.0 | 2 | |
| 0.5 | 1 | |
| 0 (initial status) | 0 (initial status) | |
| -0.5 | -1 | |
| -1.0 | -2 | |
| -1.5 | -3 | |
| -2.0 | -4 | |
| -2.5 | -5 | |
| -3.0 | -6 |
NOTE:

- When -6°F (-3.0°C) is corrected on the temperature setting set as 77°F (25.0°C) the temperature controlled by A/C auto amp. is 77°F (25.0°C) -6°F (-3.0°C) = 71°F (22.0°C) and the temperature becomes lower than the temperature setting.
- When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the difference between the set temperature and control temperature may be cancelled.