Inlet Port Memory Function (REC)
DESCRIPTION
- If the ignition switch is placed to the OFF position while the intake switch is set to ON (recirculation), "Perform the memory" or "Do not perform the memory" of intake switch ON (recirculation) condition can be selected.
- If "Perform the memory" was set, the intake switch will be ON (recirculation) when placing the ignition switch to the ON position again.
- If "Do not perform the memory" was set, the air inlets will be controlled automatically when placing the ignition switch to the ON position again.
HOW TO SET
CONSULT Select "REC MEMORY SET" in "Work support" mode of "HVAC".
| Work support items | Display | Setting |
|---|---|---|
| REC MEMORY SET | WITHOUT (initial status) | Perform the memory of manual REC |
| WITH | Do not perform the memory of manual REC (auto control) |
NOTE:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the REC memory function may be cancelled.