Inlet Port Memory Function (FRE)
DESCRIPTION
- If the ignition switch is placed to the OFF position while the intake switch is set to OFF (fresh air intake), "Perform the memory" or "Do not perform the memory" of intake switch OFF (fresh air intake) condition can be selected.
- If "Perform the memory" was set, the intake switch will be OFF (fresh air intake) when placing the ignition switch to the ON position again.
- If "Do not perform the memory" was set, the air inlets will be controlled automatically when placing the ignition switch to the ON position again.
HOW TO SET
CONSULT Select "FRE MEMORY SET" in "Work support" mode of "HVAC".
| Work support items | Display | Setting |
|---|---|---|
| FRE MEMORY SET | WITHOUT | Perform the memory of manual FRE |
| WITH (initial status) | Do not perform the memory of manual FRE (auto control) |
NOTE:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the FRE memory function may be cancelled.