DTC Diagnosis Procedure
- CHECK FUEL LEVEL SENSOR UNIT AND FUEL PUMP (FUEL LEVEL SENSOR) (MAIN) CIRCUIT
-
- Ignition switch OFF.
- Disconnect combination meter harness connector and fuel level sensor unit and fuel pump (fuel level sensor) (main) harness connector.
- Check continuity between combination meter harness connector and fuel level sensor unit and fuel pump (fuel level sensor) (main) harness connector.
Combination meter Fuel level sensor unit and fuel pump (fuel level sensor) (main) Continuity Connector Terminal Connector Terminal M77 54 M195 3 Yes - Check continuity between combination meter harness connector and ground.
Combination meter - Continuity Connector Terminal M77 54 Ground No
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Repair harness or connector.
-
- CHECK FUEL LEVEL SENSOR UNIT AND FUEL PUMP (FUEL LEVEL SENSOR) (MAIN) GROUND CIRCUIT
- Check continuity between fuel level sensor unit and fuel pump (fuel level sensor) (main) harness connector and combination meter harness connector.
Fuel level sensor unit and fuel pump (fuel level sensor) (main) Combination meter Continuity Connector Terminal Connector Terminal M195 2 M77 46 Yes
Is the inspection result normal?
YES>>
Replace combination meter. Refer to Removal and Installation .
NO>>
Repair harness or connector.
- Check continuity between fuel level sensor unit and fuel pump (fuel level sensor) (main) harness connector and combination meter harness connector.