Diagnosis Procedure
Transmits the washer fluid level switch signal to the combination meter.
- CHECK WASHER FLUID LEVEL SWITCH SIGNAL CIRCUIT
-
- Ignition switch OFF.
- Disconnect combination meter harness connector and washer fluid level switch harness connector.
- Check continuity between combination meter harness connector and washer fluid level switch harness connector.
Combination meter Washer fluid level switch Continuity Connector Terminal Connector Terminal M76 29 E82 1 Yes - Check continuity between combination meter harness connector and ground.
Combination meter - Continuity Connector Terminal M76 29 Ground No
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Repair or replace harness or connectors.
-
- CHECK WASHER FLUID LEVEL SWITCH GROUND CIRCUIT
- Check continuity between washer fluid level switch harness connector and ground.
Washer fluid level switch - Continuity Connector Terminal E82 2 Ground Yes
Is the inspection result normal?
YES>>
Inspection End.
NO>>
Repair or replace harness or connectors.
- Check continuity between washer fluid level switch harness connector and ground.