Diagnosis Procedure
Transmits the washer fluid level switch signal to the combination meter.
- CHECK WASHER FLUID LEVEL SWITCH SIGNAL CIRCUIT
- Ignition switch OFF.
- Disconnect combination meter harness connector and washer fluid level switch harness connector.
- Check continuity between combination meter harness connector and washer fluid level switch harness connector.
Combination meter
Washer fluid level switch
Continuity
Connector
Terminal
Connector
Terminal
M76
29
E82
1
Yes
- Check continuity between combination meter harness connector and ground.
Combination meter
--
Continuity
Connector
Terminal
M76
29
Ground
No
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace harness or connectors.
- CHECK WASHER FLUID LEVEL SWITCH GROUND CIRCUIT
Check continuity between washer fluid level switch harness connector and ground.
Washer fluid level switch
--
Continuity
Connector
Terminal
E82
2
Ground
Yes
Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness or connectors.