Diagnosis Procedure
- CHECK COMBINATION METER INPUT SIGNAL
- Turn ignition switch ON.
- Measure voltage between the following terminals of the combination meter.
(+)
(-)
Condition
Voltage
(Approx.)
Combination meter
Ground
Connector
Terminals
M344
44
When trip reset switch is pressed
0 V
Other than the above
5 V
51
When illumination control switch (+) is pressed
0 V
Other than the above
5 V
52
When illumination control switch (-) is pressed
0 V
Other than the above
5 V
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO 2.
- CHECK TRIP RESET AND ILLUMINATION CONTROL SWITCH SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and trip reset and illumination control switch connector.
- Check continuity between combination meter harness connector and trip reset and illumination control switch harness connector.
Terminals
Continuity
Combination meter
Trip reset and illumination control switch
Connector
Terminal
Connector
Terminal
M344
44
M83
5
Existed
51
3
52
4
- Check continuity between combination meter harness connector and ground.
Combination meter
Ground
Continuity
Connector
Terminal
M344
44
Not existed
51
52
Is the inspection result normal?
YES
GO TO 3.
NO
Repair harness or connector.
- CHECK TRIP RESET AND ILLUMINATION CONTROL SWITCH GROUND CIRCUIT
Check continuity between trip reset and illumination control switch connector and ground.
Trip reset and illumination control switch
Ground
Continuity
Connector
Terminal
M83
6
Existed
Is the inspection result normal?
YES
INSPECTION END
NO
Repair harness or connector.