LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2021 >> QX80 Premium Select, AWD >> Repair and Diagnosis >> Electrical >> Gauges >> Meter, Warning Lamp & Indicator (Diagnostics) >> Component Parts /Circuit Diagnosis >> Power Supply And Ground Circuit (Combination Meter) >> Diagnosis Procedure

Diagnosis Procedure

  1. CHECK FUSE 

    Check for blown fuses.

    Power source

    Fuse No.

    Battery

    6

    Ignition switch ACC or ON

    19

    Ignition switch ON or START

    3

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Be sure to eliminate cause of malfunction before installing new fuse.

  2. CHECK POWER SUPPLY CIRCUIT 

    Check voltage between combination meter harness connector and ground.

    Terminals

    Ignition switch position

    Voltage

    (Approx.)

    (+)

    (-)

    Combination meter

    Ground

    Connector

    Terminal

    M343

    21

    OFF

    Battery voltage

    5

    ACC

    2

    ON

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Check harness between combination meter and fuse.

  3. CHECK GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect combination meter connector.
    3. Check continuity between combination meter harness connector and ground.

      Combination meter

      Ground

      Continuity

      Connector

      Terminal

      M343

      1

      Existed

      M344

      41

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Repair harness or connector.