Component Inspection
- CHECK DOOR SWITCH
- Ignition switch OFF.
- Disconnect malfunctioning door switch connector.
- Check continuity between door switch terminals.
Door switch
Condition
Continuity
Terminal
3
Ground contact is part of the switch.
Door switch
Pressed
No
Released
Yes
Is the inspection result normal?
YES
Inspection End.
NO
Replace malfunctioning door switch. Refer to Removal and Installation .