Diagnosis Procedure
- CHECK FUSE
- Ignition switch OFF.
- Check that the following fuse is not blown (open):
Unit
Power source
Fuse No.
Capacity
Head up display unit
Ignition switch ON
21
5 A
Is the fuse blown (open)?
YES
Replace fuse after repairing the applicable circuit.
NO
GO TO 2.
- CHECK POWER SUPPLY CIRCUIT
- Ignition switch ON.
- Check the voltage between head up display unit connector and ground.
(+)
(-)
Voltage
(Approx.)
Head up display unit
Connector
Terminal
M452
13
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
Perform trouble diagnosis of ignition power supply circuit.
- CHECK GROUND CIRCUIT
- Ignition switch OFF.
- Check the continuity between head up display unit and ground.
Head up display unit
--
Continuity
Connector
Terminal
M452
24
Ground
Yes
Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace malfunctioning parts.