Component Inspection
- CHECK TRIP RESET SWITCH
- Ignition switch OFF.
- Disconnect trip reset switch connector.
- Check trip reset switch.
Trip reset switch
Condition
Continuity
Terminals
2
3
When trip reset switch is pressed
Yes
Other than the above
No
Is the inspection result normal?
YES
Inspection End.
NO
Replace trip reset switch. Refer to Removal and Installation .