Diagnosis Procedure
If any of the following malfunctions is found for the meter control switch operation.
- All switches are inoperative
- The specified switch cannot be operated
- CHECK METER CONTROL SWITCH SIGNAL CIRCUIT
Check the meter control switch signal circuit. Refer to Component Function Check .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair harness or connector.
- CHECK METER CONTROL SWITCH
a unit check for the meter control switch. Refer to Component Inspection .
Is the inspection result normal?
YES
Replace combination meter. Refer to COMBINATION METER : Removal & Installation .
NO
Replace meter control switch. Refer to METER CONTROL SWITCH : Removal & Installation .