Component Inspection
- CHECK METER CONTROL SWITCH
- Turn ignition switch OFF.
- Disconnect meter control switch connector.
- Check continuity between the following terminals of the meter control switch.
Terminals
Condition
Continuity
Meter control switch
6
4
When illumination control switch (+) is pressed
Existed
Other than the above
Not existed
7
When illumination control switch (-) is pressed
Existed
Other than the above
Not existed
5
When trip reset switch is pressed
Existed
Other than the above
Not existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace meter control switch. Refer to METER CONTROL SWITCH : Removal & Installation .