Home >> Infiniti >> 2021 >> Q50 Signature Edition, AWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter, Warning Lamp & Indicator (Diagnostics) >> Symptom Diagnosis >> Meter System >> The Trunk Open Warning Continues Displaying, Or Does Not Display >> Diagnosis Procedure

Diagnosis Procedure

  1. CHECK TRUNK LID OPEN SIGNAL CIRCUIT 
    1. Connect the CONSULT.
    2. Check the BCM input signals. Refer to Component Function Check .

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Repair or replace malfunctioning parts.

  2. CHECK COMBINATION METER INPUT SIGNAL 

    Select the "Data Monitor" for the "METER/M&A" and check the "TRUNK/GLAS-H" monitor value.

    "TRUNK/GLAS-H"

    Trunk lid open

    : On

    Trunk lid closed

    : Off

    Is the inspection result normal?

    YES

    Replace combination meter. Refer to COMBINATION METER : Removal & Installation .

    NO

    Replace BCM. Refer to BCM : Removal & Installation .